SC(B)10 Series Three Phase Resin-Cast Dry-Type Distribution Transformer

Model Series
Rated Voltage
Standard
Warranty
1 year
Application
Contact Us
Download

SC(B)10 series three phase resin-cast dry-type distribution transformer are in conformity with standard of IEC60076,with features of low loss, compact and light weight, low noise level,clamp-proof,anti-fouling,high mechanical strength, flame resisting.

General


Farady Electric manufacture a complete range of three phase distribution transformers, including oil-immersed type & cast resin dry-type transformer, we always designed with increased margins of safety and reliability,and meet the following standard:

IEC60076, IEEE Std, GB1094

Application

Strong overload ability and low partial discharge quality,they are application to power transmission and distribution system,hotel,restaurant,commercial building,stadiums,chemical plants,stations,airports,offshore drilling platforms,especially to heavy load centers and places with special fire protection requirements.

Mainly rating, types & capacity

Three phase,
Two windings or three windings
On-load or no-load voltage tapping changer
Natural cooling or force air
10-2500kVA

Service condition

  1. Suitable for indoor or outdoor application
  2. Air temperature: 
    Maximum temperature: +40℃; Minimum temperature:-30℃
  3. Humidity: 
    Monthly average humidity 95%; Daily average humidity 90% .
  4. Altitude above sea level: 
    Maximum installation altitude: 2000m.
  5. Max wind speed:35M/s
  6. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  7. No frequent violent shake
Note: * Beyond those services condition should enquiry to manufacturer technical dept during order

High reliability feature

  • Flame resistant
  • Explosion proof
  • Low temperature rise
  • Low loss & low noise
  • No environmental contamination

Technical Specification (11kv Series)

Type Voltage combination Vector group Loss(W) Impedance% Dimension(L*W*H)mm Weight
Primary(KV) Tapping range Secondary(KV) No Load loss Fullload loss (kg)
SC(B)10-30/10 6 ±2x2.5% 0.4 or other Yyn0 or 190 700 4 680*400*686 300
SC(B)10-50/10 6.3 Dyn11 270 990 690*400*686 360
SC(B)10-80/10 6.6 360 1370 730*450*796 500
SC(B)10-100/10 10 400 1570 730*500*816 600
SC(B)10-125/10 10.5 470 1840 780*600*950 700
SC(B)10-160/10 11 540 2120 950*650*1124 850
SC(B)10-200/10 13.2 620 2520 990*650*1164 950
SC(B)10-250/10 13.8 720 2750 1020*650*1207 1100
SC(B)10-315/10 15 880 3460 1050*750*1320 1250
SC(B)10-400/10 970 3980 1100*800*1450 1550
SC(B)10-500/10 1160 4880 1140*800*1430 1850
SC(B)10-630/10 1340 5870 1250*800*1500 1900
SC(B)10-800/10 1520 6950 6 1330*800*1540 2200
SC(B)10-1000/10 1760 8120 1400*960*1640 2750
SC(B)10-1250/10 2090 9690 1450*960*1690 3300
SC(B)10-1600/10 2450 11730 1560*960*1930 4000
SC(B)10-2000/10 3320 14450 1680*960*1930 4800
SC(B)10-2500/10 3600 17170 1720*1010*1950 5500

Note: *The above parameter is only subject to our standard design, special requirement can be customized.

(20kv Series)

Type Voltage combination Vector group Loss(W) Impedance% Dimension(L*W*H)mm Weight
Primary(KV) Tapping range Secondary(KV) No Load loss Fullload loss (kg)
SC(B)10-30/20 20 ±2x2.5% 0.4 or other Yyn0 or 220 800 6 980*480*750 435
SC(B)10-50/20 22 Dyn11 340 1240 1100*480*780 522
SC(B)10-80/20 24 410 1500 1160*500*800 725
SC(B)10-100/20 540 2000 1200*510*850 870
SC(B)10-125/20 580 2100 1200*600*900 1015
SC(B)10-160/20 680 2470 1220*650*1124 1233
SC(B)10-200/20 740 2950 1250*650*1164 1378
SC(B)10-250/20 800 3200 1280*670*1207 1595
SC(B)10-315/20 970 4090 1300*750*1400 1813
SC(B)10-400/20 1150 4850 1320*800*1450 2248
SC(B)10-500/20 1350 5800 1350*800*1490 2683
SC(B)10-630/20 1530 6840 1360*800*1530 2755
SC(B)10-800/20 1760 8270 1380*800*1580 3190
SC(B)10-1000/20 2070 9790 1430*960*1680 3988
SC(B)10-1250/20 2390 11540 1470*960*1720 4785
SC(B)10-1600/20 2790 13870 1560*960*1800 5800
SC(B)10-2000/20 3240 16390 1790*960*1930 6960
SC(B)10-2500/20 3870 19380 1800*1010*1950 7975

Note: *The above parameter is only subject to our standard design, special requirement can be customized.

(35kv Series)

Type Voltage combination Vector group Loss(W) Impedance% Dimension(L*W*H)mm Weight
Primary(KV) Tapping range Secondary(KV) No Load loss Fullload loss (kg)
SC(B)10-30/35 33 ±2x2.5% 0.4 or other Yyn0 or 300 1350 6.5 1000*500*750 544
SC(B)10-50/35 34.5 Dyn11 380 1490 1180*530*780 653
SC(B)10-80/35 35 500 1950 1190*550*800 906
SC(B)10-100/35 640 2400 1220*560*850 1088
SC(B)10-125/35 750 2640 1240*600*900 1269
SC(B)10-160/35 820 3100 1260*670*1124 1541
SC(B)10-200/35 900 3700 1290*690*1164 1722
SC(B)10-250/35 1080 4350 1320*700*1207 1994
SC(B)10-315/35 1250 4400 1380*780*1400 2266
SC(B)10-400/35 1550 5660 1400*830*1450 2809
SC(B)10-500/35 1800 6970 1430*850*1490 3353
SC(B)10-630/35 2070 8120 1460*890*1530 3444
SC(B)10-800/35 2430 9630 1500*910*1580 3988
SC(B)10-1000/35 2700 11070 1520*960*1680 4984
SC(B)10-1250/35 3150 13400 1540*980*1720 5981
SC(B)10-1600/35 3600 16200 1590*1000*1800 7250
SC(B)10-2000/35 4230 19100 1830*1020*1930 8700
SC(B)10-2500/35 4950 22900 1900*1090*1950 9969

Note: *The above parameter is only subject to our standard design, special requirement can be customized.